Concrete

Calibrated dynamometer rings for more accurate performance on site

Met de dienst metrologie biedt certificatie-organisme BE-CERT vzw deskundige ondersteuning bij het beheer van technische uitrusting.
Met de dienst metrologie biedt certificatie-organisme BE-CERT vzw deskundige ondersteuning bij het beheer van technische uitrusting.

Through its metrology service, certification body BE-CERT vzw provides expert support with the management of technical equipment. At the customer's request, BE-CERT vzw carries out periodic or occasional inspections to calibrate, verify and check equipment. An important part of the service is the calibration of dynamometer rings. “The importance of a perfectly calibrated measuring instrument is still too often underestimated,” emphasises Koen Derboven, head of metrology at BE-CERT vzw.

Construction companies with laboratories and businesses in the industrial sector can contact BE-CERT vzw at any time to arrange a technical inspection visit. During such visits, presses, scales, drying ovens and sieves are calibrated, humidity and temperature are verified, and other equipment is also checked using calibrated instruments. Following an intervention by experienced technicians, the customer receives a report giving an overview of the accuracy and precision of their measuring instruments. A quick and efficient on-site intervention, both in Belgium and abroad, or at BE-CERT vzw's own laboratory, helps keep downtime to a minimum. Koen Derboven: “By taking measurements, we trace all results back to an international standard. We visit customers to check the equipment they use to carry out tests and then trace the results back to these international or national standards.” 

“By calibrating the dynamometer ring, we link a specific force to a specific deformation of the ring, measured by the integrated strain gauge.”

BELAC accreditation

BE-CERT is BELAC-accredited (510-CAL and 510-TEST) to carry out calibrations. Koen Derboven: “This gives the customer the assurance that all our procedures and equipment are used correctly and meet all the required standards. For example, a laboratory scale complies with the applicable standard once we have calibrated it and traced the measurement back to the international standard. We do the same for various types of equipment.”

Construction companies with laboratories and businesses in the industrial sector can contact BE-CERT vzw at any time to arrange a technical inspection visit.

Dynamometer ring

The metrology service's main connection with civil engineering is the calibration of dynamometer rings, a component of the equipment used on site to measure soil compaction in preparation for laying foundations. Koen Derboven: “A dynamometer ring is essentially a metal ring with a small integrated strain gauge. The ring is installed in a frame at the rear of the lorry, with a plate of a specific diameter beneath it. During the measurement, the lorry is then used as a counterweight to transfer the loads specified in Standard Specification 250 to the plate. By calibrating the dynamometer ring, we link a specific force to a specific deformation of the ring, measured by the integrated strain gauge. In other words, we convert the force that needs to be applied to the plate into the number of millimetres of deformation in the ring.”

Correctly calibrated equipment ensures accurate measurements and properly executed work, meaning far fewer unpleasant surprises and potential repair costs later on. This also highlights the importance of calibration and inspection. Koen Derboven: “A lot of uncalibrated equipment is still being used. Contractors assume that equipment will remain perfectly adjusted after purchase, but in reality that is certainly not always the case. We cannot rule out that some settlement in our roads or sewers is due to measurements being taken with uncalibrated equipment. If the initial measurement is already inaccurate, the entire structure will be wrong too.”

The metrology service's main connection with civil engineering is the calibration of dynamometer rings

Not yet mandatory

Nevertheless, Koen Derboven sees a positive trend over the long term. “I have been in the business for 25 years and have certainly noticed growing interest in and attention to these kinds of inspections. But there is still room for improvement, of course. It is important to raise awareness among people in the sector and explain the potentially serious consequences of very small measurement errors. Standard Specification 250 does explain clearly how to use the equipment, but inspection or calibration is still not mandatory. As the only BELAC-accredited body for dynamometer rings, BE-CERT vzw naturally wants to take a leading role in this area,” Koen Derboven concludes.     

Een zakelijke vraag aan PROCERTUS? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeMaterials with a lower environmental impact
  • SubjectConcrete
  • CompanyPROCERTUS
Share this article

Follow Grond/Weg/Waterbouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.