Concrete

Large-scale concrete repairs in Brussels tunnels

Text and images Sanacon

Sinds eind 2021 is Sanacon bezig met het grootschalig renovatiedossier van de Brusselse tunnels in het tracé van de binnenring R20.
Sinds eind 2021 is Sanacon bezig met het grootschalig renovatiedossier van de Brusselse tunnels in het tracé van de binnenring R20.

Since late 2021, Sanacon has been working on the large-scale renovation programme for the Brussels tunnels along the R20 inner ring road. These tunnels date from the 1950s, 1960s and 1970s, and are therefore due for a thorough overhaul.  

More specifically, Sanacon is actively involved in the renovation of the concrete roof slabs of the following tunnels:

For 4 of these 7 tunnels, Sanacon is providing the complete design and sizing of the cathodic protection system, and advising on the benefits and necessity of cathodic protection for the remaining tunnels. Sanacon also advises specialist contractors on practical implementation and assesses the impact of the works on the stability of the roof slabs so that appropriate measures can be taken in good time.

Mathias Maes: “Tackling these tunnels as a single package and at almost the same time reflects a sound approach to managing infrastructure in the Brussels-Capital Region. This is complemented by the excellent choice of highly effective techniques, such as impressed-current cathodic protection. We are also pleased to see that the focus is first on maintaining the concrete infrastructure, rather than, as we often see, investing considerable attention, time and money in cosmetic improvements and new technologies, such as replacing the lights, while pieces of concrete are still at risk of falling. This approach addresses the real problems in a practical and logical way.”

For 4 of the 7 tunnels, Sanacon is providing the complete design and sizing of the cathodic protection system, and advising on the benefits and necessity of cathodic protection for the remaining tunnels.

Sanacon has already demonstrated its approach during the renovation of the Annie Cordy Tunnel

(formerly the Leopold-II tunnel) in 2018-2019, showing that relevant investigation data can be used to define a targeted repair method based on the type and severity of any deterioration mechanisms. Comparing carbonation depth, chloride profiles and concrete cover, while accounting for the spread of the data and spatial variability, makes it possible to estimate the risk of damage caused by reinforcement corrosion. The progression of the damage over time can also be determined. To do this, Sanacon uses its newly developed DIMCOST software. The most suitable techniques for managing the risks are then considered together with the infrastructure managers or contractors (in the case of DB(F)M projects).

As part of the ongoing renovations, where damage is already advanced, large areas of loose concrete are removed and calculations are made to determine how this should be managed during the works.

“This approach is now being used again,” says Bjorn Van Belleghem. “When renovation work began on the Troon, Naamsepoort, Tervuren and Boileau tunnels, the plan was already to use cathodic protection. Sanacon is responsible for designing and sizing the cathodic protection system, as well as preparing the construction drawings that the contractor can use to install it. For a number of other tunnels, cathodic protection was not initially intended as a repair strategy. However, further inspections and analyses showed that cathodic protection was better suited to certain sections of the tunnels, where the concrete was found to be heavily contaminated with chlorides, for example where a tunnel crosses other major roads.”

When renovation work began on the Troon, Naamsepoort, Tervuren and Boileau tunnels, the plan was already to use cathodic protection.

Sanacon is also assessing the impact of the necessary repairs on the stability of the tunnel roof slabs. “As part of the ongoing renovations, where damage is already advanced, large areas of loose concrete are removed and calculations are made to determine how this should be managed during the works. We then develop a proposal for temporary propping, or opt to carry out the work in alternating sections,” says Lander Vasseur.

In principle, all the services Sanacon can offer for concrete repairs are being used on these projects, from investigation, analysis and advice through to the design and sizing of cathodic protection systems, preparation of construction drawings and site supervision. This is how the sustainable preservation of our concrete infrastructure becomes a reality.

In principle, all the services Sanacon can offer for concrete repairs are being used on these projects.

Een zakelijke vraag aan Sanacon bv? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeExtending the life of bridges and tunnels
  • SubjectConcrete
  • CompanySanacon bv
Share this article

Advertisement

Follow Grond/Weg/Waterbouw Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.