Extend the service life of your concrete structure

Corrosion is always a risk. Especially in reinforced concrete, the right approach must be followed to limit and prevent corrosion. Master Builders Solution is launching MasterProtect 8500 CI, a new corrosion inhibitor developed for application to both new and existing structures.
Corrosion can be defined as the conversion of a refined metal into its more stable oxides through the action of oxygen and water. Concrete provides a natural shield that protects steel reinforcement against corrosion. The highly alkaline environment created by the cement matrix around the reinforcement forms a passive layer around the bar, specifically an impermeable oxide layer that prevents further corrosion by completely isolating the steel surface. However, this protective layer remains intact only as long as the highly alkaline environment of the cement matrix is maintained. Carbonation caused by exposure to carbon dioxide dissolved in water reduces the pH of the cement matrix. Chloride ions also disrupt the passive layer and lead to corrosion. If the passive layer breaks down, corrosion reactions occur and damage the steel reinforcement.

Master Builders Solution is launching MasterProtect 8500 CI, a new corrosion inhibitor developed for application to both new and existing structures
Although the corrosion process cannot be avoided, a great deal can be done to slow it down. Various types of corrosion inhibitor are available on the market. They consist of chemical compounds that prevent corrosion reactions on reinforcing steel. All inhibitors must reach the steel reinforcement within the concrete to protect it. Corrosion inhibitors can therefore be added to concrete admixtures and mixed directly into fresh concrete, or applied to the surface of hardened concrete (surface-applied corrosion inhibitors). The first type can only be used on new structures, while the second has been developed specifically for the refurbishment of existing structures.
MasterProtect 8500 CI
There is no need to choose between the ideal solution for new and existing structures. MasterProtect 8500 CI from Master Builders Solution is a new corrosion inhibitor developed for application to both new and existing structures, and has proved effective even when cracks form after the coating has been applied. MasterProtect 8500 CI is a dual-action, silane-based corrosion inhibitor applied to the surface. It is suitable for use as part of a corrosion prevention, protection or mitigation strategy. This revolutionary blend of high-performance silanes and selective corrosion inhibitors remains dormant within the concrete until activated by moisture entering the surface through cracking or concrete deterioration.
The inhibitor is invisible when the concrete is dry, as MasterProtect 8500 CI does not change its appearance. When the concrete is wet, however, its water-repellent effect, known as beading, is clearly visible on the surface. MasterProtect 8500 CI also has a very low viscosity, which improves penetration into concrete across a wide temperature range, a lower VOC content and a higher flash point. Together, these properties make the product much easier and safer to handle and apply than many other inhibitors.

It is suitable for use as part of a corrosion prevention, protection or mitigation strategy.
Dual action
What does the dual action of MasterProtect 8500 CI mean, and how does it work? Conventional surface-applied corrosion inhibitors must penetrate deep into the concrete to reach the steel reinforcement. There, the functional group acts directly on the surface of the bars, repassivating the steel and reducing both active and future corrosion. With its dual action, MasterProtect 8500 CI goes one step further.
One aspect of the dual action of MasterProtect 8500 CI is the water-repellent effect of its high-performance silane blend, which prevents moisture and chlorides from entering the concrete. Depending on the chemical reaction, silanes with different functions can be formed. MasterProtect 8500 CI uses several types of silane to produce different effects on the concrete substrate. These include a corrosion-inhibiting effect and the formation of a water-repellent layer that protects the concrete against the ingress of liquids while allowing water vapour to pass through. This prevents new moisture from entering the concrete, while allowing any moisture already present in the substrate to evaporate. This keeps the concrete dry and increases its electrical resistance. Since concrete can be considered an electrolyte for steel reinforcement, higher resistance prevents electrochemical reactions. In dry, alkaline concrete, the reinforcement is also rapidly passivated. The lack of water and the high resistance of the concrete drastically reduce the rate of corrosion.
The dormant inhibitor is blended with the silanes and forms the second element of MasterProtect 8500 CI’s dual action. The presence of dormant inhibitors is crucial to protecting reinforced concrete structures against corrosion over the long term. Structures are very likely to develop cracks at some point, regardless of the age or quality of the concrete. Reinforced concrete tends to crack for various reasons. Cracking also means that the water-repellent shield created by the silanes in MasterProtect 8500 CI is no longer effective. Water and chloride ions can enter through the crack and damage the steel reinforcement. This is where the dual action comes into play, allowing MasterProtect 8500 CI to continue protecting the reinforcement. The latent inhibitors remain dormant in the concrete until the water-repellent properties diminish over time or the concrete cracks. They are then activated, become mobile and are carried deeper into the concrete by moisture. The steel reinforcement therefore remains protected.
MasterProtect 8500 CI stands out from the many existing inhibitors on the market thanks to its dual action: alongside the water-repellent shield created by the revolutionary silane blend, the dormant inhibitor provides long-term protection. This can extend the service life of all types of reinforced concrete structures. Its effectiveness has been demonstrated by several independent tests.
Een zakelijke vraag aan Master Builders Solutions Belgium nv? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeMaterials with a lower environmental impact
- SubjectConcrete
- CompanyMaster Builders Solutions Belgium nv