A sustainable alternative to PFAS incineration
Text Valérie CouplezImage iStock

It starts with measuring PFAS contamination. The next step is to remove it from the soil or water. But what do you do with it then? Today, PFAS mainly ends up in incinerators, where temperatures can be raised to above 1,200 °C, preferably even 1,400 °C, to effectively destroy the chains. There are none in the Netherlands, but there is one in Antwerp. STOWA, the Dutch knowledge centre for regional water authorities, has therefore commissioned research into a potential new route for destroying PFAS. It combines PFAS degradation in a ball mill with chemically regenerable adsorbents such as DEXSORB. A more sustainable alternative.
Currently, the most common method for (largely) destroying PFAS is to incinerate heavily PFAS-laden granular activated carbon (GAC), but this has its limitations. On the one hand, suitable incinerators have limited capacity and availability. On the other, PFAS degradation is incomplete, resulting in PFAS being deposited in the surrounding environment. A promising alternative is the mechanochemical degradation of PFAS using a ball mill. The ball mill destroys PFAS using energy generated by friction and collisions between the balls. This energy, combined with hydroxide ions, creates the reactive conditions needed to break down the PFAS chains. The technology can be paired with chemically regenerable adsorbents such as zeolites, GAC and cyclodextrins, including DEXSORB®. During the feasibility study, regeneration was carried out using a solvent consisting of an ethanol/water mixture, which desorbs the adsorbed PFAS from the DEXSORB granules. Regeneration produces a water/ethanol stream containing dissolved PFAS and other desorbed micropollutants. The regenerant is collected, after which the following process steps are carried out.

Destruction efficiency of up to 99%
As the ball mill requires a dry substance, this study assessed the process steps needed to achieve a complete regeneration and destruction route. The selected destruction route consists of concentration and evaporation steps that follow the Zero Liquid Discharge (ZLD) concept: membrane filtration followed by vacuum evaporation and an advanced drying step using spray drying. This feasibility study confirmed that the ball mill achieves a high destruction efficiency (95 to 99%) when destroying pure PFAS in the laboratory. DEXSORB also achieves a sufficiently high regeneration efficiency in a single regeneration cycle. Multiple regeneration cycles are expected to enable almost complete regeneration of the adsorbent (> 95%). The study also shows that the new destruction route is technically feasible and has a CO2 footprint four times lower than incinerating GAC, making it much more sustainable than the current incineration route. With a single regeneration cycle, this amounts to 8.3 tonnes of CO2/kg PFAS. A sensitivity analysis shows that this result is not affected by the remaining uncertainty about energy consumption during the destruction route. The difference is mainly due to the difference in specific adsorption capacity between DEXSORB and GAC (g PFAS/kg adsorbent).
Next steps
The steering committee has given its support, with a positive recommendation, to starting a practical study to demonstrate the ‘Proof of Principle’ of using a ball mill to destroy PFAS. This follow-up study will consist of laboratory research divided into two phases. The first phase will focus on PFAS in a groundwater matrix, given its relatively low complexity and the availability of PFAS-laden DEXSORB. The technology will be investigated without interference from more complex matrices such as those that may occur in wastewater. The second phase will focus on PFAS in a municipal wastewater matrix, which is more complex because of possible interference from other micropollutants or organic matter. This research is made possible by the availability of PFAS-laden DEXSORB from a pilot using DEXSORB on the effluent of the municipal wastewater treatment plant RWZI Dordrecht. This can ultimately provide the basis for developing a business case that also allows an objective cost comparison.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeUsing and protecting the subsurface
- SubjectGeneral